Applications

The Basic Structure Of GIE Optics Spectrometer

Selection Of Spectrometer

Choose the appropriate spectrometer according to different measurement applications

Model Standard Spectrometer
UV-Visible Spectrometer
Mars HS2000+/HS3000+/HS6000+
High-Speed Spectrometer
UV-Visible Spectrometer HP3000 Plus
High-Resolution Spectrometer (4096pixels/3648pixels/2048pixels)
HRS4000/HRS3000/HRS2000
High Resolution and High Sensitivity Spectrometer HRS2000-BT(2048pixels)
Near-Infrared Spectrometer
(128pixels/256pixels/512pixels)
Explorer NIR
Photo
Specification Wavelength Range:180-1100nm (customized)
Integration Time: 0.5ms-65sec
Sensor:
Hamamatsu S11639-1 Slit=25um (50um/100um/200um)
Optical Resolution : 0.5-12nm
Wavelength Range:180-1100nm(customized)
Integration Time:0.1ms-65sec
Sensor:
Hamamatsu S11639-1 Slit=25um (50um/100um/200um)
Optical Resolution : 0.5-12nm Data Rate, 2ms/frame
Wavelength Range:200-1100nm (customized)
Sensor:
Toshiba 3648pixels Hamamatsu 4096pixels
Integration Time: 0.5-65sec Slit=5um /10um
Optical Resolution: 0.1-0.2nm
Wavelength Range:950-1700nm/900-2500m
Sensor:
Hamamatsu InGaAs 128 pixels Hamamatsu InGaAs 256 pixels
Hamamatsu InGaAs 512 pixels
Integration Time: 0.1-65sec Slit=25um /50um Optical Resolution: 4-6nm
Model High Sensitivity Spectrometer
Venus Pro-UV, Venus Pro-NIR
NIR TE-Cooling Spectrometer(512pixels/256pixles)
Explorer NIR-TEC
UV-VIS TE-Cooling Spectrometer(2048pixels/1024pixels)
SR2000-TEC/SR1000-TEC
Spectra Module MS2000/MS3000
Photo
Specification Wavelength Range:180-1100nm (customized)
Sensor:
Hamamatsu S10420
Back thinned CCD
Hamamatsu S16010(S11510)
Back thinned CCD
Slit=5μm/10μmm/25μm/50μm
Optical Resolution:0.35nm - 1.5nm
Wavelength rang: 900-2500nm
Sensor:
Hamamatsu 512 pixels with TE-cooling
Hamamatsu 256 pixels with TE-cooling
Pixel Size : 25×250μm
Optical Resolution :
Depends on customer’s needs
Wavelength range (nm):180-1100nm
Sensor:
Hamamatsu back-thinned CCD sensor
Pixels: 1024×58 Pixels
Pixel Size: 24µm×24µm
Wavelength Range
200nm-950nm(Default specifications)
Optical Resolution: ~1nm
(Pre-configured 25µm slit)
Wavelength range (nm):950-1700nm
180-1100nm (customized)
Sensor:
Hamamatsu S11639-1
Slit=10um/25um (50um/100um/200um)
Optical Resolution : 0.5-12nm

Spectrometer Applications

Plasma Monitoring

Model: Mars HS2000+
Wavelength Range: 180-900nm,
Slit=10μm,
Optical Resolution ~ 0.8nm

Model : HRS4000
Wavelength Range :180-1000nm (customized)
Slit=5μm,
Optical Resolution ~ 0.1nm

Transmittance/Absorption Measurement

Plan1:

Directly use the SEM-3000 multi-function measurement system for measurement.

Plan2:

The experiment can be equipped with customized measurement fixtures to measure the transmittance of samples of different sizes.

The transmittance spectrum of the sample

The absorbance spectrum of the sample

Reflectance Measurement

Different reflectance measurement fixtures can be used to measure the reflectance of transparent samples (glass coating) and non-transparent material samples (wafer).

Concentration Measurement

1.Beer's Law Calculate Concentration

2.Calculate concentration based on measurement data of known

3.Calibration curve can be established

Relative Radiant Intensity And Colorimetric Measurement

Absolute Intensity and Colorimetric Measurements

Irradiance Calibrate

If you have a standard light source, you can calibrate the radiation intensity yourself.